Hazard

Aluminium rivets were used instead of steel rivets for the fixings for the draught diverter plate. Failure of the rivets could lead to the draught diverter plate moving out of position which, in combination with the failure of the safety cut off switch, could cause carbon monoxide to enter the room.The product does not comply with the requirements of the Gas Appliances Directive.

Measures taken

  • Warning consumers of the risks — Manufacturer (16/03/2017)
  • Retro fit of adaption plate to prevent baffle plate movement — Distributor (16/03/2017)

Product description

Chimney/flue gas-fired heaters, no packaging.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.