Skip to content

Ante lighting chain "led-háló karácsonyi ég" — electric shock & fire risk

EU Safety GateSerious riskElectric shockFireMay 4, 2012
Photo from the official notice: Ante lighting chain "led-háló karácsonyi ég" — electric shock & fire risk
Photo from the official notice: Ante lighting chain "led-háló karácsonyi ég" — electric shock & fire risk

Photos from the official notice: EU Safety Gate (European Commission) · image rights

Hazard

The product poses a risk of electric shock and fire because:·         The cross-sectional area of the wires is not sufficient and the wires can consequently overheat.·         The wire ends soldered to the rectifying unit terminals and the LEDs are not adequately protected against pulling and twisting. ·         The accessible wires have only basic insulation and if they come into contact with the sharp edges of the rectifying unit live wires can become accessible. The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.

Product description

Lighting chain with 40 serial connected, non-replaceable LED lamps.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

More from this brand

See all →

Recent alerts in this category

See all →