"Bottari" manual illuminator — electric shock risk

EU Safety GateSerious riskElectric shockJun 16, 2006

Hazard

The product poses a risk of electric shock because it suffers from insufficient fastening of the cable, the cross-section of main cable is smaller then required (0,43mm2), the product did not pass the bent test (all cable conductors broke down) and the marking does not comply with the requirements (wrong voltage indication, essential symbols are missing).The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market ordered by the authority — Other

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.