Aquarium Light “BOYU” Aquarium Light lighting equipment — electric shock & fire risk

EU Safety GateSerious riskElectric shockFireOct 6, 2006

Hazard

- A nylon tie was used as cord anchorage. The cord could twist and be pushed into the luminaries, putting strain on the terminals. The conductors could become loose from the terminals and short-circuit.- There was no lamp holder. The wiring was connected directly to the lamp using metal shell-shaped bushes. While replacing the lamp these bushes are accessible and must be removed by hand. This product does not comply with the relevant standard - EN 60598-1.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authority — Other

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.