Skip to content

Lighting chains — electric shock & fire risk (0625/06)

EU Safety GateSerious riskElectric shockFireOct 6, 2006

Hazard

The products pose a risk of:<b>+ electric shock because</b>:- the insulation of the wires does not meet the requirements;- the PVC insulated wires are not suitable for outdoor use;- the flashing unit and the lamp holders are not protected against ingress of water; - the cross section area of the wires is less than required;- the wire inlets of the flashing unit are sharp so the wires can get damaged; - the wires are not fixed against loosening. <b>+ fire because</b>:- the power input is too high (126 W instead of the required 50W);- the resistance of the plastic parts of the lamp holders to ignition is not sufficient.The products do not comply with the Low Voltage Directive and the relevant standard EN 60598.

Measures taken

  • Sales ban ordered by the authority — Other

Product description

Lighting chain (CEDAR). 1) 160 plug-in type miniature incandescent lamps and 8-function flashing unit, 2) 240 plug-in type miniature incandescent lamps and 8-function flashing unit.Description: Products consist of 160/240 series parallel connected non-replaceable incandescent lamps with resistor bridge. The flashing unit controls 4 parallel-connected circuits for flashing the plug-in type light sources. Main parts: bipolar plug with inscription: CH 2.5 A 250 V~ TS-01 VDE; flashing unit with inscriptions: FLASHER CONTROL UNIT 220V AC 50HZ 0.83A PRESS + names of functions. Technical specifications: 230V; 50Hz; 5 V; 0,13 mA; 104 W/125W; by appearance Class II, IP20.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

Recent alerts in this category