Lighting equipment — electric shock & fire risk (0679/06)
Hazard
This product poses a risk of electric shock and injury because:- the luminaire fails the test with spring-operated hammer (with impact energy of 0,7Nm) and ‘fall test’ (height 850mm); in both cases lampshade becomes detached; - during the tests, accessible parts of the lamp reach temperature of 118° C (maximum allowed temperature for accessible non-metallic parts is 75° C); - connector for adaptor 12 Va.c. fails the ball-pressure test at 125° C;- measured diameter of impression is 5mm (maximum allowed diameter of impression is 2mm).This product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
Measures taken
- Sales ban ordered by the authority — Other
Product description
Portable luminaire for children “Hartig & Hellig“
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.
Recent alerts in this category
- Candle Warmer Lamp, TL-167 — electric shock riskUK OPSSSeriousOct 21, 2026· Lighting equipment
- LED Ceiling Light, JM6001 — fire riskUK OPSSSeriousOct 20, 2026· Lighting equipment
- Inflatable balloon - LED lamp led inflatable balloon lamp — environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Dinosaurie skrivbord barn desk lamp — chemical & environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Frideko Home LED Floor Lamp sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Frideko Home· Lighting equipment
- OOWOLF LED Light sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Oowolf· Lighting equipment



