Skip to content

Unknown. lighting chain. — electric shock risk (0072/07)

EU Safety GateSerious riskElectric shockJan 26, 2007

Hazard

The product poses a serious risk of electric shock because:- the cable incorporated into the chain does not meet the type-cable specifications of the standard,- the conductor section is 0.06 mm², which is less than the 0.50 mm² required by the standard,– the cable did not pass the tensile test,– the length of the cable between the plug and the first lamp-holder is 1.00 metres, which is less than the 1.50 metres required by the standard,– there are no safety marks or safety instructions.This product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Import of the product rejected by the customs authorities — Other

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.