Skip to content

Horse Power. electric saw - combined mitre-bench saw. — injuries risk

EU Safety GateSerious riskInjuriesJan 26, 2007

Hazard

The product poses a serious risk of injury because:- the width of the top guard is too wide, - the deflection of the top guard is too big when the guard is pulled laterally with a force of 5N,- the maximum distance between the riving knife and the saw blade is too big,- the riving knife must be turned out when the function of the saw is changed. Because it is difficult to turn out the riving knife, the user probably takes it away, - the mechanical strength of the combined user/emergency switch is weak and damaged by a stroke. As a result, the function of the emergency stop is also damaged. There is therefore a danger of contact with moving parts and danger of failure of guards and the user/emergency switch.The product does not comply with the Machinery Directive and the relevant European standard EN 61029.

Measures taken

  • Voluntary recall from consumers by the importer — Other

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

Recent alerts in this category

See all →