Christmas lighting chain — electric shock & fire risk

EU Safety GateSerious riskElectric shockFireApr 5, 2007

Hazard

There is a risk of electric shock and fire because the cross-sectional area and length of conductors as well as size of the plug outlet are not in compliance with Article 5 of standard EN 60598. As the parameters of the conductors do not comply with the European standard (they are thinner as laid down), there is a risk that during the use of the product the conductors can overheat and cause an electric shock. The bulb sockets are not made from self-extinguished material and fail to stand the needle flame test based on Article 13 of standard EN 60598. Therefore, there is a danger of spread of fire and electric shock in certain circumstances. This product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Sales ban and recall from consumers ordered by the authority — Other

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.