Markslöjd/Bergen incandescent floor lamp — electric shock risk

EU Safety GateSerious riskElectric shockJun 15, 2007

Hazard

This product poses a serious risk of electric shock because :- the locking screw of the joint of the bracket penetrates into the wire ways. When the screw is tightened, internal conductors are pressed between the joint and the screw. When the luminaire is adjusted, the screw grinds the insulation of the conductor;- the luminaire is a self-assembly product. In the instructions it is stated that the screw shall be tightened. During the electric strength test, after about 20 adjustments, there was a breakdown at a voltage of ca 500 V. The requirement is 3670 V after 1500 adjustments;- the creepage distance over the bushing of the opening of the flexible cord to the metal main part is only about 1 mm, it shall be minimum 3.6 mm. Creepage distance between the conductor of the supply cord and metal body is about 0.6 mm, it shall be minimum 3.6 mm. There is no protective sleeve at the bifurcation of the cord.This product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Recall from consumers ordered by the authorities — Other

Product description

Floor-standing incandescent luminaire which main parts are made of metal.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.