Skip to content

EM&EM portable lamp — burns & electric shock risk

EU Safety GateSerious riskBurnsElectric shockAug 3, 2007

Hazard

The product poses a serious risk of electric shock and burns because in the fitting spliced flexible wire conductors have been fully tinned and installed in terminals that do not ensure an elastic clamp, which may be a reason of falling out of the conductor from the terminal, and thus cause the decrease of the isolating clearances or a shock, as well as in case of loosening of the wire–terminal contact it could cause sparking and overheating of the contact. Moreover the product and its packing contained contradictory information regarding the maximum power of a bulb – 40 W and 25 W respectively.This product does not comply with the Low Voltage Directive and with the relevant European standard EN 60598.

Measures taken

  • Voluntary withdrawal from the market by the manufacturer — Other

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

More from this brand