Skip to content

LUCERNA wall light — fire risk

EU Safety GateSerious riskFireSep 21, 2007

Hazard

This product poses a serious risk of fire because:- deformation of die-casting occurred at temperature 125 ºC, - pellet impress diameter is 7,3 mm whereas the limit is 2 mm,- after testing with acicular flame, the material of product has ignited,- after testing with burning loop at temperature 850 ºC the material immediately set on fire without any chance of the fire to get extinguished spontaneously. The material kept on burning after the loop had been pushed aside. The material also failed after testing at temperature 750 ºC.This product does not comply with the Low Voltage Directive and the relevant European standard EN-60598.

Measures taken

  • Voluntary withdrawal from the market and information to consumers by the distributor — Other

Product description

The light was sold in the cardboard box marked as follows: "Lighting equipment LUCERNA TL 3020 15W, 230V/50Hz, type of pentad G13" and CE mark. The product was labelled with a typical label marked as follows: "LUCERNA, model: TL 3020/15W, 230V/50 Hz, G13/154W:IP20" and CE mark.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.