Skip to content

REDLINE. impact drill. — electric shock & injuries risk

EU Safety GateSerious riskElectric shockInjuriesOct 12, 2007

Hazard

The product poses :- serious risk of electric shock because when replacing the main cable the internal wiring and brush holders moves from their original position, thus the proper arrangement of the wiring cannot be controlled, they can get pinched between the two plastic parts of the cover, furthermore the live wires can get into contact with accessible metal parts.- moderate risk of injuries because many of the general safety rules are missing in the instructions for use.The product does not comply with the Machinery Directive and the relevant European standard EN 60745.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authority — Other

Product description

The product has plastic cover with rubber insert at the grip. Main parts of the device: mains plug (10/16A 250V~ D02 QINOPU+marks of test houses); mains cable (H05VV-F YONGKANG CITY HUAQIANG CABLE AND WIRE FACTORY 2X0,75mm2; VDE); switch including control circuit and selector of direction of rotation (FA2-6/1BEK. The package contains a pair of carbon brush, a 3-m tape-measure and 5 drills. Technical specification: 230V~; 50Hz; 760W; 0-2600r/min; 13mm; Class II.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

More from this brand

See all →

Recent alerts in this category

See all →