Skip to content

LANDIA DELPHI floor lamp — electric shock risk

EU Safety GateSerious riskElectric shockJan 25, 2008

Hazard

The product poses risk of electric shock because the flexible mains cable rubs against the supporting surface under the uncovered base part when moving the luminaire, thus the cable may get damaged.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

The package includes the components of the luminaire ready for assembly (metal base part, plastic counter weight, metal upper and lower tube and lamp shade). Three lampholders in 120° are fitted onto the upper tube. The lamp shade is a paper-like cylinder. Main parts of the luminaire: mains plug (2.5A 250V~ SV-2402 SH502); mains cable (SAHMET INTERNAT-C H03VVH2-F 2X0,75mm2 IEC227); switch inserted into the cable (MADE IN ITALY 565 2[2]/250~ 41-23884; ENEC; CE); E14 plastic lampholders (2/250 T210 22.223; ENEC; VDE). Technical specifications: 230V~50Hz; 3X40W, lampholder: E 14, Class II, F-mark.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.