Elman 8695 and Elman 8693 wall luminaire — electric shock risk
Hazard
The product poses a risk of electric shock because there is not sufficient electrical insulation between the circuit connected to the mains and the part that can be touched. - KH209E: The creepage distance between the connector of the switch and the actuator of the switch is less than 6.5 mm; measured 1.1mm. - KH209C: The creepage between the live terminal of the switch and the unearthed metal actuator of the switch is less than 6.5 mm; measured 1.1 mm.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
Measures taken
- Withdrawal from the market and recall from consumers ordered by the authorities — Other
Product description
Wall luminaire with LEDs, surface mounted.
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.
Recent alerts in this category
- Candle Warmer Lamp, TL-167 — electric shock riskUK OPSSSeriousOct 21, 2026· Lighting equipment
- LED Ceiling Light, JM6001 — fire riskUK OPSSSeriousOct 20, 2026· Lighting equipment
- Inflatable balloon - LED lamp led inflatable balloon lamp — environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Dinosaurie skrivbord barn desk lamp — chemical & environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Frideko Home LED Floor Lamp sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Frideko Home· Lighting equipment
- OOWOLF LED Light sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Oowolf· Lighting equipment