Elman 8695 and Elman 8693 wall luminaire — electric shock risk

EU Safety GateSerious riskElectric shockFeb 15, 2008

Hazard

The product poses a risk of electric shock because there is not sufficient electrical insulation between the circuit connected to the mains and the part that can be touched. - KH209E: The creepage distance between the connector of the switch and the actuator of the switch is less than 6.5 mm; measured 1.1mm. - KH209C: The creepage between the live terminal of the switch and the unearthed metal actuator of the switch is less than 6.5 mm; measured 1.1 mm.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

Wall luminaire with LEDs, surface mounted.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.