Skip to content

ENERGY + cable reel — electric shock risk

EU Safety GateSerious riskElectric shockJul 18, 2008

Hazard

The product poses a risk of electric shock because :- during the bending test, when rotating the complete cable around a mandrel with diameter 40 mm at temperature of -35(±2)°C, it showed cracks both at the sheath and at the insulation, causing the wires of the conductors to become accessible,- during the impact test, 200 g mass from height 100 mm at -25±2°C temperature, the samples showed cracks at the sheath. The product does not comply with the Low Voltage Directive and the relevant European standards EN 61242 and EN 60811.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

Black cable reel with rubber cable length of 20 m.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.