Skip to content

NET LIGHT lighting chain for indoor use - 160l net light — electric shock risk

EU Safety GateSerious riskElectric shockSep 12, 2008

Hazard

The product poses a risk of electric shock because:- the cross-section of the core is smaller than the minimum requirement (0.5 mm2); the measured value is less than 0.15 mm2,- the plug does not meet the requirements of the standard.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

The lighting chain contains 160 series-parallel connected incandescent lamps with a resistor bridge. The lamps are non-replaceable. Main parts of the luminaire are: bipolar plug with inscription: "2.5 A 250 V~ ASIA 777 VDE 06"; two-core mains cable. Technical parameters: on the packaging: 220V-240V~ 50 Hz; 2,5A 250W; Class II, IP20; on the product: 230V~ 50Hz, 33,6W, IP20, bulb: 3V, 70mA.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.