MY cord extension set - puutarhapistorasia av-2005 — electric shock risk
Hazard
The product poses a risk of electric shock because :- during various tests the cable showed cracks both at the sheath and in the insulation resulting in the wires of the conductors becoming accessible;- the temperature of the terminals rose in excess of 100 K in circuits L-earth, when it should not exceed 45 K;- The measured contact pressure of the earthing contacts is 0-4.9 N, when it shall not be less than 5 N;- the measured distance between the side-earthing contacts is 30.3 mm and 30.4 mm, which exceeds the requirement of 29 mm +0/-1 mm.The product does not comply with the Low Voltage Directive and with the relevant European standard EN 60811.
Measures taken
- Withdrawal from the market and recall from consumers ordered by the authorities — Other
Product description
Cord extension set with two socket-outlets and a rubber cable of length 1.5 m.
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.
Recent alerts in this category
- Innovagoods Fotmassageapparat massager — environment riskEU Safety GateSeriousOct 23, 2026· Innovagoods· Electrical appliances and equipment
- Leg and arm moylding massage instrument calf massager — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment
- Electric Neck Massager — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment
- Jancheng Electric Neck Massage Tool neck massager — environment riskEU Safety GateSeriousOct 23, 2026· Jancheng· Electrical appliances and equipment
- Massager cervical Vertebra neck massager — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment
- Elektrisk nagelfil nail file — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment