Skip to content

Chang Hong lighting chain - jégcsap égö — electric shock risk

EU Safety GateSerious riskElectric shockOct 17, 2008

Hazard

The product poses a risk of electric shock because : - there is only basic insulation on the soldered connections of the light sources, - the cross-section area of the core is less than the requirement, - the wires broke when checking the cord anchorage, - the protection against ingress of water is missing. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

The product is a lighting chain containing 224 series-parallel connected, incandescent, non-replaceable lamps with resistor bridge. There are flashing unit controls and four parallel circuits. Mains plug with inscription: " CH, TS-01, 2,5A 250V, VDE "; flashing unit with inscription: "FLASHER CONTROL UNIT 230V AC 50HZ 0.83A CE TÜV EMC PRESS". Technical parameters: 230 V~, 50 Hz, 55 W, Class II.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.