Skip to content

Royal lighting chain – md 0604 — electric shock risk

EU Safety GateSerious riskElectric shockOct 17, 2008

Hazard

The product poses a risk of electric shock because: - the length of the cord between the mains plug and the first lampholder is too short (0.98 m), - there is only basic insulation on the soldered connections of the light sources, - the cross-section of the core is less than the requirement, - the cable inlets are sharp, - cord anchorage is missing. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market ordered by the authorities — Other

Product description

Lighting chain including 240 miniature non-replaceable incandescent lamps with resistor bridge and an 8-function flashing unit. The flashing unit controls four parallel circuits. Mains plug with inscription: "2.5 A 250 V~ VDE CE"; flashing unit with inscription: "FLASHER CONTROL UNIT 230V AC 50HZ 0.83A CE TÜV EMC PRESS"; mains cable without marking. Technical parameters: 230 V~, 50 Hz, 63.7 W, Class II, IP20, 9 V, 70 mA.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

More from this brand

See all →