Royal lighting chain — electric shock risk (1176/08)

EU Safety GateSerious riskElectric shockOct 17, 2008

Hazard

The product poses a risk of electric shock because : - there is only basic insulation on the soldered connections of the light sources, - the cross-section area of the core is less than the requirement, - cord anchorage is missing in the flashing unit. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

Lighting chain including 180 miniature, non-replaceable, incandescent lamps with a resistor bridge and an 8-function flashing unit. The flashing unit controls four parallel circuits. Mains plug with inscription: "2.5 A 250 V~ VDE CE"; flashing unit with inscription: "FLASHER CONTROL UNIT 230V AC 50HZ 0.83A CE TÜV EMC "; 2-core mains cable without marking. Technical parameters: 230 V~, 50 Hz, 104 W, Class II, IP20, bulbs: 2,2 V, 0,07A; F-mark