PHU lighting chain - fairy lights with 100 lamps — electric shock & fire risk

EU Safety GateSerious riskElectric shockFireDec 5, 2008

Hazard

The existing conductor cross section is about 0.15 mm², the required cross section is 0.5 mm², thus overload is possible, as the function is that of an extension cord with accompanying luminaire. The conductor insulation does not fulfill the requirements for double insulation according to EN 60598-2-20, thereby it can be easily damaged.

Measures taken

  • Withdrawal from the market ordered by the authorities — Other

Product description

Indoor chain of lights with 100 little jack lamps, extendable, with a Euro plug 230 V, 50 Hz, max. 35 W