SIRIJUS cord extension set " ilgintuvas" — electric shock & fire risk
Hazard
The product poses a risk of electric shock and fire because: - the cross-section area of the cable is 1.0 mm² which is lower than the required 1.5 mm²,- the electric conductor resistance is higher than the permissible limit. The product does not comply with the Low Voltage Directive and the relevant European standard IEC 60884.
Measures taken
- Sales ban and withdrawal from the market and recall from consumers ordered by the authorities — Other
Product description
Cord extension set with 3 outlets. Technical characteristics: -250V, 16A, 3500 W, safeguard rate IP20. The cord extension set is packed in a transparent plastic bag. Cable connexion – under mountable, Type of cable - H05VV-F, cross-section of cable – 1.0 mm².
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.
Recent alerts in this category
- Innovagoods Fotmassageapparat massager — environment riskEU Safety GateSeriousOct 23, 2026· Innovagoods· Electrical appliances and equipment
- Leg and arm moylding massage instrument calf massager — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment
- Electric Neck Massager — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment
- Jancheng Electric Neck Massage Tool neck massager — environment riskEU Safety GateSeriousOct 23, 2026· Jancheng· Electrical appliances and equipment
- Massager cervical Vertebra neck massager — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment
- Elektrisk nagelfil nail file — environment riskEU Safety GateSeriousOct 23, 2026· Electrical appliances and equipment