bdnc extension cable — electric shock & fire risk (0727/09)

EU Safety GateSerious riskElectric shockFireJun 5, 2009

Hazard

The product poses a risk of electric shock and fire because: - neither the plug or the socket block comply with the requirements, - the average resistance between the earth connection and the accessible metal parts is 0.09Ω, whereas that specified by the standard is ≤ 0.05Ω, - portable sockets that can be dismantled must have threaded connectors, whereas in this case the connections are welded, - construction of plugs and socket-outlets is non compliant, - the minimum section for the power cable conductors of devices with current up to 16 Amperes and 250 Volts is 1 mm², whereas the conductors on this sample have a section of 0.3 mm²,- although this extension cable can be dismantled, it is fitted with conductors of 0.3 mm² (marking on the cable indicate that the section is 1 mm²), - the values measures for clearances and creepage are lower (2.7 mm) than the specified values (3 mm), - the resistance of insulating material to abnormal heat, to fire and tracking is insufficient. The product does not comply with the Low Voltage Directive.

Measures taken

  • Withdrawal from the market ordered by the authorities — Other

Product description

White-coloured extension cable with a 1.5 m power cable, 3 “Schuko” sockets, a switch and the following dimensions: 16.5 x 4.5 x 4 cm.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

More from this brand

See all →

Recent alerts in this category

See all →