Skip to content

NTH lighting chain - 140 l darabos — electric shock risk

EU Safety GateSerious riskElectric shockAug 28, 2009

Hazard

The product poses a risk of electric shock because:- the wires connecting the miniature lamps have only single insulation, - the cross section area of the core of the wire is less than required, - the cable inlets of the flashing unit have sharp edges, - there is no protection against pulling force in the flashing unit.This product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

The lighting chain includes 140 db series-parallel connected non-replaceable lamps with resistor bridge. The flashing unit controls 4 parallel circuits. Main components: bipolar plug (2.5 A 250 V~); flashing unit (FLASHER CONTROL UNIT 230 V AC 50 HZ 0.83 A CE TÜV EMC NTH PRESS); two-core mains cable without marking. Technical parameters: 230 V~, 50 Hz, Max 65 W, Class II, IP20, bulbs: 6.5 V, 0.07 A 0.455 W.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

More from this brand