Skip to content

Kraftwelle portable gasoline generator — electric shock & fire risk

EU Safety GateSerious riskElectric shockFireSep 11, 2009

Hazard

The product poses a risk of :1. electric shock, because:- the live components of the electrical conductors are easily accessible,- the electrical conductors are not sufficiently insulated, - the circuit breaker installed is not suitable for this generator;2. fire, because when the generator is switched off to be refuelled after operation, the exhaust temperature is still higher than 230°C. Given the ignition temperature of petrol (200-300°C), there is a potential danger of ignition and skin burns. The product does not comply with the Machinery Directive (98/37/EC), the Low Voltage Directive (LVD) and the relevant European standards EN 12601 and EN 60204.

Measures taken

  • Sales ban ordered by the authorities — Other

Product description

Generator Standard Set Q/FMH001-1996Red generator contained in a black carry frame, with three 230 V sockets and one red 400 V socket.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

More from this brand

See all →

Recent alerts in this category

See all →