ÖZCAN light fitting — electric shock risk

EU Safety GateSerious riskElectric shockFeb 12, 2010

Hazard

The product poses a risk of electric shock because:- the mains cable and the internal wiring can get damaged because they are in contact with sharp edges;- the terminal block is not properly fixed in position and accessible metal parts may come into contact with only basic insulated parts.The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market ordered by the authorities — Other

Product description

Light fitting. Three non-adjustable metal brackets are fixed to a wooden plate, and a G9 lamp holder and a decorative cube is fitted to each bracket. There is a terminal block (marking: ATILIM ENEC14 ATL3 450V 24A ) on the other side of the wooden plate. Technical parameters: 230 V, 50 Hz, Class II, light source: 3xG9, maximum 40 W.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.