Skip to content

Lighting chains — electric shock risk (0621/05)

EU Safety GateSerious riskElectric shockDec 2, 2005

Hazard

The voltage (220V) indicated on the package differs from the one used in Hungary (230V). Flexible, single-insulated wire is applied between the plug and the flashing unit and the lamps insulated by heat shrink tube, soldered into the wire. The cross-sectional area of the wire is <0,1 mm2. The bushing of the flashing unit is not rounded off. The flexible wires soldered to the bushing are not supplied with conductor relief. The single-core wire comes off the soldering under force of 13,5N. The plug is not of standardized type.

Measures taken

  • Distribution of a product prohibited by the authority — Other

Product description

Lighting chain ‘MULTI FUNCTION 100 RICE LIGHT’, the package with 100 pieces of not replaceable miniature lamps and with a flashing unit of 8 functions.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.