Lighting equipment — electric shock risk (0655/05)
Hazard
Risk of electric shock. The nipple is not locked at the cable inlet of the E 14 lamp holder, not secured against loosening, thus live parts may become accessible.The lamp does not comply with the LVD Directive and the European Standards.
Measures taken
- Prohibition of distribution ordered by the authority — Other
Product description
Desk lamp in a form of a butterfly "Tiffany" (230V~; E14; Max. 40W, Class II).Type/model: TK-716.
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.
Recent alerts in this category
- Candle Warmer Lamp, TL-167 — electric shock riskUK OPSSSeriousOct 21, 2026· Lighting equipment
- LED Ceiling Light, JM6001 — fire riskUK OPSSSeriousOct 20, 2026· Lighting equipment
- Inflatable balloon - LED lamp led inflatable balloon lamp — environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Dinosaurie skrivbord barn desk lamp — chemical & environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Frideko Home LED Floor Lamp sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Frideko Home· Lighting equipment
- OOWOLF LED Light sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Oowolf· Lighting equipment



