Eco Light Nordic led lamp tube — electric shock risk (0966/10)

EU Safety GateSerious riskElectric shockJun 25, 2010

Hazard

The product poses a risk of electric shock because:- during mounting the free-end connector of the LED tube might be live;- the clearance and the creepage distances are not sufficient;- the insulation resistance is not sufficient;- internal basic insulated conductors are in contact with the metal body of the lamp;- the mechanical strength of the silicone insulation of the conductors is weak and can be easily damaged.The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.

Measures taken

  • Withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

LED lamp tube intended to replace a traditional fluorescent tube in the original (existing) luminaire.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.