Skip to content

Lighting chains — electric shock & fire risk (0669/05)

EU Safety GateSerious riskElectric shockFireDec 23, 2005

Hazard

Creepage distances and clearances for live parts and accessible parts are less than the required values: plate: cr: 4,62mm, plate: cl: 3,2m (instead of ≥ 6,5mm). The conductors’ cross-sectional area is 0,10mm2 (instead of ≥ 0,50mm2). Internal wiring Cross-sectional area: 0,10mm2 (must be ≥0,50mm2). There is no cord anchorage on the flashing unit. The length of the cable between the plug and the first lamb is 1,0m (instead of ≥1,5m). User instructions only in English and French. There in no warning to inform the consumers that this is an indoor lightening chain only.This product does not comply with the LVD Directive and the European Standard.

Measures taken

  • Withdrawal from the market ordered by the authority — Other

Product description

Lighting chain with flashing unit and 100 miniature lamps "100 Pearl Lights"

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.