Lighting equipment — electric shock & fire risk (0673/05)
Hazard
The mains cable provided with a switch is directly connected to the lamp holder. The luminaire assemble has only basic insulation and the wires are accessible by the standard test finger. If the insulation get damaged electric shock may occur. The cord anchorage is not appropriate. The dimensions of the plug do not comply with the standard. The temperature of the internal PVC wire was 79,1°C (while the maximum value is: 75°C).
Measures taken
- Withdrawal from the market and placing on the market prohibited by the authority — Other
Product description
Snail-formed luminaire "Tiffany"Type/model: TK-717; 230V~ rated voltage
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.