Lighting equipment — electric shock risk (0679/05)
Hazard
Inadequately insulated live wires at the bottom of the product can be touched. Cross-section of mains has only 0.3 mm² (standard stipulates 0.75 mm²). High-voltage test failed. Incorrect lamp fitting E 10 (permitted up to 60 volts only). Air gap and creep distance at lamp fitting has only 0.4 mm (min. 3.6 mm required). Instructions are available only in English. None of the markings prescribed in the standard are present.The product does not comply with the LVD Directive and the European Standard.
Measures taken
- Placing on the market prohibited by the authority — Other
Product description
Electric lighting "Disco Light"Type/model: QL-114, EAN 6920570519945.
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.