Electrical appliances and equipment — electric shock risk (0714/05)

EU Safety GateSerious riskElectric shockJan 6, 2006

Hazard

The conductors of the supply cord have nominal cross sectional area 0,75mm2, whereas the less permitted cross sectional area is 1mm2.The withholding hook of the sample does not protect the conductors from twisting. The withholding hook of the supply cord is not sufficient. The length of the earth conductor is such that it does not ensure that the earth conductor will disconnect after the disconnection of the live conductors, in case the supply cord gets out of the withholding hook. The screws inside the insulating material of the sample cause damage to the insulating materialThis product does not comply with the LVD Directive and the European Standard.

Measures taken

  • Withdrawal from the market ordered by the authority — Other

Product description

Cordless kettle "Best" for household use.Type/model: HEK-8009.