Skip to content

Rucejok electric pump — electric shock risk

EU Safety GateSerious riskElectric shockNov 12, 2010

Hazard

The product poses a risk of electric shock because:- submersible pump shall be a Class I (on the pump Class II), - the connection plug is Class I, but without earth connection wire conductor,- power cord wire cross-sectional area smaller than the limit of 0.75 mm² (measured 0.5 mm²),- lack or wrong instructions.The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60335.

Measures taken

  • Sales ban, withdrawal from the market and recall from consumers ordered by the authorities — Other

Product description

Electric pump packed in a cardboard box.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

Recent alerts in this category