Hazard

The basic insulated internal wiring was led through sharp and burring edges. The wire of the conductor connected to the terminal gets into contact with accessible metal live parts. There was neither protective earth provided with the luminaire nor indication of Class II. Since the protective earth is missing accessible metal parts get into contact with basic insulated conductors (double insulation is missing). These products do not comply with the LVD Directive and the European Standards.

Measures taken

  • Withdrawal from the market and recall ordered by authority — Other

Product description

Wall-luminaires "Sevinc Aydinlatma" 1. Double wall-bracket; type/model: 2065/2.A (type version: 2060/2.A).2. Single wall-bracket. 2080/1.A (type versions: 2065/1.A; 2060/1.A; 2005/1.A).