Skip to content

Electrical appliances and equipment — electric shock risk (0112/06)

EU Safety GateSerious riskElectric shockMar 10, 2006

Hazard

Creepage distances and clearances in the mains transformer between the primary windings and secondary windings / between the primary windings and output winding wires of the secondary windings / between the secondary windings and output winding wires of the primary windings are less than 4 mm; measured a minimum of 0.2 mm. The secondary circuit is accessible through the terminals. The windings are positioned concentrically on a single coil former and wounded on the edge of the coil former. This product does not comply with the LVD Directive and the European Standards.

Measures taken

  • Recall from consumers ordered by the authority — Other

Product description

Power supply unit for portable DVD player.Type/model: FJ-SW2545XY.

What should I do?

If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.

Recent alerts in this category