Skip to content

Dream Cast Light — electric shock risk

UK OPSSSerious riskElectric shockSold on AmazonNov 3, 2022

Hazard

The product presents a serious risk of electric shock because it is inadequately earthed. The earth wire had not been connected inside the floodlight. The resistance between the earthing terminal and earthed metal parts exceeded the 0.5 Ω limit, and the cross-sectional area of the earth wire was so small that it melted when the test current was passed through it. The cross-sectional area of the conductors / supply cords was unacceptable. Additionally, the supply cord sheaths had split at the point of entry to the floodlight case allowing access to basic insulation on the conductors. The product does not comply with the marking requirement of the relevant standard nor the Electrical Equipment (Safety) Regulations 2016.

Remedy

The listing has been removed by the online marketplace (Amazon). Destruction of the product at the border.

Product safety report

Measures taken

  • Destruction of the product
  • Removal of listing by online marketplace

Product description

UA rectangular shaped outdoor floodlight with multiple light emitting diodes

What should I do?

If you own this product, stop using it and follow the corrective action above: contact the retailer or supplier for a repair, replacement or refund. This notice was published by the UK Office for Product Safety and Standards.

Recent alerts in this category