Skip to content

Schueco Solar (Photovoltaic) Cells — electric shock risk

UK OPSSHigh riskElectric shockNov 28, 2022

Hazard

The product has been identified as presenting a high risk of electric shock. Investigations identified ‘chalking’ on the backing of solar panels, which can occur over time and result in cracks forming along the internal connector of the module. These cracks can lead to voltage transmission from the module to the frame, which could result in an individual receiving an electric shock if they are touching the panel when this voltage transmission occurs.

Remedy

The manufacturer has issued a safety warning letter to consumers setting out the potential risks presented by the product. Affected product will require being taken out of operation or isolated such that access to the modules is prevented. Switching off the module (inverter) is not sufficient to remove the risk. Affected consumers should follow the information set out in the safety warning letter. Further information is available on the following webpage: Schuco Warning Letter on Product Safety - Photovoltaics

Product safety report

Measures taken

  • Warning consumers of risks

Product description

Solar modules with ‘Ico-solar 3554’ backing foil.

What should I do?

If you own this product, stop using it and follow the corrective action above: contact the retailer or supplier for a repair, replacement or refund. This notice was published by the UK Office for Product Safety and Standards.