Italmecc Air Box 2100 — health risk

Photos from the official notice: UK Office for Product Safety and Standards (GOV.UK) · image rights
Hazard
The product instructions do not include adequate instructions for installation, specifically, the requirement for ducting extracted air to outside. When used in accordance with the instructions without being ducted to outside, the machine does not effectively control exposure to hazardous substances generated during the intended use of the machine, including respirable dust. This is of particular concern when used to control dust generated by processing materials containing respirable crystalline silica (RCS). Exposure to RCS poses a serious health risk. This product does not meet the requirements of the Supply of Machinery (Safety) Regulations 2008.
Remedy
Italmecc S.R.L. have stopped supply in GB until the machine instructions are updated and brought into compliance. The GB supplier provides additional information to persons supplied regarding the installation of ducting with this machine and have agreed to continue to do this, unless alternative equally effective measures are determined by the manufacturer. Users of these machines should ensure that they are ducted to outside when used to control exposure to substances hazardous to health, or use other equally effective measures.
Product safety report
Measures taken
- Other
Product description
A water backed booth LEV system designed to capture and filter dust produced during stone processing.
What should I do?
If you own this product, stop using it and follow the corrective action above: contact the retailer or supplier for a repair, replacement or refund. This notice was published by the UK Office for Product Safety and Standards.
Recent alerts in this category
- Yongkang MinRui Electric Tool Plant 21V Cordless Drill Driver Kit electric drill — electric shock riskEU Safety GateSeriousOct 23, 2026· Machinery
- Glowica tarcza do kosy spalinowej attachment for brush cutter — injuries riskEU Safety GateSeriousOct 23, 2026· Machinery
- Uniwersalna glowica do podkaszarki attachment for brush cutter — injuries riskEU Safety GateSeriousOct 23, 2026· Machinery
- Uniwersalna głowica do podkaszarki attachment for brush cutter — injuries riskEU Safety GateSeriousOct 23, 2026· Machinery
- Faster Tools circular saw blade — cuts riskEU Safety GateSeriousOct 16, 2026· Faster Tools· Machinery
- Mini Chainsaw, 4L — electric shock riskUK OPSSSeriousOct 13, 2026· Machinery