BRILUX recessed luminaire — electric shock risk (0340/08)
Hazard
The product poses risk of electric shock because:- the basic-insulated parts (terminal block and single insulated wires) are accessible, - it lacks device protecting against pulling and twisting force,- plastic bushings are missing at the entry hole which has sharp metal edges,- the PVC insulated internal wiring overheats at the measured value of 107°C.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
Measures taken
- Withdrawal from the market and recall from consumers ordered by the authorities — Other
Product description
The metal-covered luminaire provided with aluminium mirror consists of a metal frame and a fitting unit fixed to the frame with riveting. The fitting unit includes the E27 ceramic lampholder and a terminal block. Main components: lampholder ("250V 660W), terminal block ("380V 10A" + mark of approval), internal wiring ("GB5023.3-1997 227IEC 02(RV) 300/500V"). Technical specifications: 230 V; 50 Hz; max 60 W E27; Class I; F-mark, IP20.
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.
More from this brand
- Brilux "Pont lámpatest, stabil" (still spotlight) built-in spotlight — electric shock riskEU Safety GateSeriousSep 19, 2014· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock & fire risk (0405/08)EU Safety GateSeriousApr 11, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock risk (0350/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock risk (0349/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock & fire risk (0348/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock & fire risk (0342/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
Recent alerts in this category
- Candle Warmer Lamp, TL-167 — electric shock riskUK OPSSSeriousOct 21, 2026· Lighting equipment
- LED Ceiling Light, JM6001 — fire riskUK OPSSSeriousOct 20, 2026· Lighting equipment
- Inflatable balloon - LED lamp led inflatable balloon lamp — environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Dinosaurie skrivbord barn desk lamp — chemical & environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Frideko Home LED Floor Lamp sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Frideko Home· Lighting equipment
- OOWOLF LED Light sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Oowolf· Lighting equipment