BRILUX recessed luminaire — electric shock & fire risk (0405/08)
Hazard
The product poses a risk of :1. Electric shock because:- sharp edges protrude into the wireways,- the bushings are not properly fixed,- there is no device to protect against pulling and twisting force,- the earth is led through a painted surface,- internal wiring overheats - the basic insulated wires are accessible. 2. Fire: since the ballasts can significantly overheat The product does not comply with the Low Voltage Directive and with the relevant European EN 60598.
Measures taken
- Withdrawal from the market and recall from consumers ordered by the authorities — Other
Product description
The metal cover of the luminaire is orange. An approx. 26x26 cm aluminium reflector with mat glass is fitted onto the 35x19x10 cm base. The base is suitable for hosting two G24-d-3 lamp holders for compact fluorescent lamps of 26 W and two chokes. Main components: chokes (BRILUX Model FL26, 230 V 50 Hz, tw 90, #t70), terminal block (HAOMENG, PA 10, CE), G24-d-3 lamp holders (EMC 2A/250 CE). Technical specifications: 230 V; 50 Hz; 2*26 W; Class I; F-mark; IP 20.
What should I do?
If you own this product, stop using it and check the official notice for what the seller or authority advises (return, refund, repair or disposal). Measures listed here were reported by national authorities to the EU Safety Gate system.
More from this brand
- Brilux "Pont lámpatest, stabil" (still spotlight) built-in spotlight — electric shock riskEU Safety GateSeriousSep 19, 2014· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock risk (0350/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock risk (0349/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock & fire risk (0348/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock & fire risk (0342/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
- BRILUX recessed luminaire — electric shock risk (0340/08)EU Safety GateSeriousMar 21, 2008· Brilux· Lighting equipment
Recent alerts in this category
- Candle Warmer Lamp, TL-167 — electric shock riskUK OPSSSeriousOct 21, 2026· Lighting equipment
- LED Ceiling Light, JM6001 — fire riskUK OPSSSeriousOct 20, 2026· Lighting equipment
- Inflatable balloon - LED lamp led inflatable balloon lamp — environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Dinosaurie skrivbord barn desk lamp — chemical & environment riskEU Safety GateSeriousOct 16, 2026· Lighting equipment
- Frideko Home LED Floor Lamp sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Frideko Home· Lighting equipment
- OOWOLF LED Light sold via Amazon — electric shock riskUK OPSSOct 13, 2026· Oowolf· Lighting equipment