Emerson Sempell GmbH Valve Fastener — chemical risk

UK OPSSSerious riskChemicalJul 24, 2026
Photo from the official notice: Emerson Sempell GmbH Valve Fastener — chemical risk

Photos from the official notice: UK Office for Product Safety and Standards (GOV.UK) · image rights

Hazard

The product presents a serious risk of injury as the product specifications require that zinc-plating is used on the fasteners. Testing confirmed that cadmium-plating had been used during the manufacturing process. There is a risk that the incorrect plating on the fasteners can cause the bolt to fracture at temperatures exceeding 232°C which could result in process leakage, serious injury or property damage. The Fasteners do not comply with the Pressure Equipment (Safety) Regulations 2016 and the applicable standards, EN 10204-3.1 and EN 10204-3.2

Remedy

The product has been recalled by Sempell GmbH, who have contacted affected customers directly with a Safety Notice.

Product recall

Measures taken

  • Recall of product from end users

Product description

Plated fasteners for pressure valves and assemblies.

What should I do?

If you own this product, stop using it and follow the corrective action above: contact the retailer or supplier for a repair, replacement or refund. This notice was published by the UK Office for Product Safety and Standards.