Fluke Test Lead - Model 3PHVL-17XX — electric shock risk

UK OPSSHigh riskElectric shockJul 7, 2023
Photo from the official notice: Fluke Test Lead - Model 3PHVL-17XX — electric shock risk
Photo from the official notice: Fluke Test Lead - Model 3PHVL-17XX — electric shock risk
Photo from the official notice: Fluke Test Lead - Model 3PHVL-17XX — electric shock risk

Photos from the official notice: UK Office for Product Safety and Standards (GOV.UK) · image rights

Hazard

The black moulded plastic insulators covering the neutral banana jack terminals of the affected cables are brittle and may crack during the factory assembly process or through stresses expected from normal operation/reasonable use. During installation/removal of the black N-terminal conductor from an electrical installation the presence of a crack in the insulation may allow direct contact to the conductor or a voltage transient to arc to the user potentially leading to electric shock. The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

Remedy

Fluke has stopped shipping the affected cables and has informed distributors to stop selling the products with the affected cables and to return any units in their stock to Fluke for replacements. End users/customers have been contacted regarding the potential safety risk with instructions to stop using the cables register for a free replacement of the cables. The recall notice has been sent to the UK distributors / customers and the link to the specific UK website is the following: https://www.fluke.com/en-gb/support/safety-notices/17xx-quadcable-recall

Product recall

Measures taken

  • Recall of product from end users

Product description

The product is a 4-conductor test lead accessory that is interconnected to a Fluke power quality analyser used in electrical installation for measurement purposes. The three conductors for phase connections have red 4mm shrouded banana jack terminals whereas the single conductor for the neutral connection has black terminals. The recalled cables are sold separately as 3PHVL-17XX Cable Replacement Kits and are included with the following kits: Fluke-3540 Power Monitors, 173x Series Power Loggers, 174x Series Power Quality Loggers and 177x Series Power Quality Analysers.

What should I do?

If you own this product, stop using it and follow the corrective action above: contact the retailer or supplier for a repair, replacement or refund. This notice was published by the UK Office for Product Safety and Standards.