Skip to content

CPSC, Fluke Corp. Announce Recall of Digital Multimeters

U.S. CPSCBurnsElectric shockAug 19, 2002
Recalled Fluke Digital Multimeter
Recalled Fluke Digital Multimeter

Photos from the official notice: U.S. Consumer Product Safety Commission · image rights

Hazard

The recalled units can take longer than normal, up to 18 seconds, to display readings of AC voltages above 500 volts. Users can misinterpret the delayed reading to mean that high voltage is not present. If high voltage is present, users could be exposed to a risk of shock, electrocution, and thermal burns.

Remedy

Consumers should stop using these testers immediately and contact Fluke for information on returning the recalled unit for a free repair.

Incidents & injuries

Fluke has received four reports from Canada and Australia, in which users experienced a delayed response, while measuring high voltage, though no injuries were reported.

Product description

Multimeters are used to measure voltage, resistance and current. The recalled Fluke digital multimeters measure up to 1,000 volts alternating current (VAC) and direct current (VDC). "Fluke" and "175", "177" or "179" are written on the front of the unit. The tester body is yellow and black, and measures about 7.25 inches long by 3.5 inches wide. Recalled units have a serial number below 79000000. The serial number is written on the back of the instrument, under the hinged stand.

Sold on

Home and hardware stores and industrial distributors nationwide sold these testers, from January 2001 through October 2001, for between $170 and $215.

Contact the company

Consumers should call Fluke at (800) 260-4819 between 8 a.m. and 7 p.m. ET Monday through Friday or at the Fluke website www.fluke.com/170recall

What should I do?

Stop using the product and follow the remedy below. Contact the company for a refund, repair or replacement — recall remedies are free.

More from this brand

See all →

Recent alerts in this category

See all →